دوره 6، شماره 4 - ( 8-1397 )                   جلد 6 شماره 4 صفحات 37-28 | برگشت به فهرست نسخه ها

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Pourmahdi N, Zeinoddini M, Dehghan Esmatabadi M J, Sheikhi F. Simple and Rapid Detection of Yersinia Pestis and Francisella Tularensis using Multiplex-PCR. Res Mol Med (RMM) 2018; 6 (4) :28-37
URL: http://rmm.mazums.ac.ir/article-1-293-fa.html
Simple and Rapid Detection of Yersinia Pestis and Francisella Tularensis using Multiplex-PCR. Research in Molecular Medicine. 1397; 6 (4) :28-37

URL: http://rmm.mazums.ac.ir/article-1-293-fa.html


چکیده:   (2760 مشاهده)
Background: Yersinia pestis and Francisella tularensis cause plague and tularemia, which are known as diseases of the newborn and elderly, respectively. Immunological and culture-based detection methods of these bacteria are time-consuming, costly, complicated and require advanced equipment. We aimed to design and synthesize a gene structure as positive control for molecular detection of these bacteria.
Materials and methods: Conserved regions of each bacterium were determined. A fragment containing the fopA and caf1 genes (conserved genes of F. tularensis and Y. pestis, respectively) was artificially synthesized, cloned into the pUC57 vector (pUC-fopA-caf1), transformed into E. coli DH5α, and used in a multiplex PCR assay. The sensitivity of this assay was examined by serial dilution of the extracted plasmid, whereas the specificity was examined using genomes of Escherichia coli, Salmonella typhi, Enterobacter aerogenes, Vibrio cholerae as templates. Finally, PCR products were analyzed in agarose gel electrophoresis.
Results: As expected, our analysis showed a clear dual band in the size range of 107 bp to 176 bp, confirming the presence of fopA and caf1 genes. Another 351 bp band was detected due to amplification being dependent on the forward primer of fopA and the reverse primer of caf1. Optimization of the PCR protocol reduced the amplification of this 351 bp band. The sensitivity of this assay was determined to be 36×10 -3 ng/µl and the selectivity test confirmed the specificity of this method is appropriate for the detection of target genes.
Conclusion: This multiplex PCR method could be used in research laboratories for identification of these important pathogens.
متن کامل [PDF 3000 kb]   (1562 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: زیست شناسی مولکولی
انتشار: 1397/8/24

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به Research in Molecular Medicine می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Research in Molecular Medicine

Designed & Developed by : Yektaweb